• Main burner ignition using a 120V hot surface igniter. • Flame rectification circuit to monitor flame presence. • Monitoring of system pressure switch, high temperature limit, and rollout functions. • Appliance operation/safety requirements controlled via microprocessor. • Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM™ thermostat. • LED system status, performance and diagnostic indication. • Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances. • Twinning capability • EnviraCOM™ communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control.
Description Universal single stage heating & cooling Line Voltage 120Vac (97-132 Vac) Low Voltage 24V (18-30Vac) Frequency 60 Hz Operating Temperature (F) -40 F to +175 F Operating Temperature (C) -40 C to +79 C Operating Humidity Range (% RH) 0% to 95% non-condensing Igniter Current 1.0A resistive @ 95Vac output Thermostat Anticipator Setting (Stage 1 only) 100mA PrePurge 30 seconds HSI Warmup Time 17/27 or 30/30 seconds Trial For Ignition 4, 6, or 8 seconds PostPurge 15 seconds Interpurge 60 secods Ignition Trials Three, two tries if flame is not sensed Flame Failure Response Time 2 Seconds max @ 1µA Number of LEDs 3 Heat On Fan Delay 30 or 60 seconds Heat Off Fan Delay 60, 90, 120, or 180 Seconds Cool Fan On Delay 5 seconds Cool Fan Off Delay 0 or 60 seconds Gas Control Used With Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended. Cooling Contactor Used With Any 24Vac contactor rated at 1.0A or less Induced Draft Blower Load 2.2FLA / 25LRA max @120Vac Ciculator Load 14.5FLA / 25LRA max @120Vac Type of Fan Used With Standard Induction-Type Circulating Fan
This module is used on hundreds of furnace models check the cross reference
United Technologies: 1012-925A, 1012-925B, 1012-925C, 1012-955A, 1012955A, 1012-83-9651B, 1012-930, 1012933D, 1012-933D, 1012-83-9336AHSC1, 1012-83-9337A
Rheem, Ruud or Robertshaw: 62-24268-01, 62-24268-02, 62-24268-03
Nordyne: 624557, 6245570, 624557-0, 624564, 6245640, 624591, 624591A, 624591-A, 624591-B, 624591-C, 624591-D, 624628, 624628-D, 6246310, 624631-0, 624631A, 624631-A, 624631-B, 710128A, 902378, 902696, 903106
Carrier or Bryant: 903106, CARB1809913S, CAR3310192200, CAR03101973000, CAR50A55843
Texas Instruments: 6DT-1, 6DT-2, 61F3
York: 03100662000, 031-00662-000, 031-00662-700, 031-01140-000, 031-01140-001, 031011140002, 031-01140-002, 031-01140-701, 031-01140-702, 031-01234-000, 031-01234-700, 031-01235-700, 031-01250-000, 0310126700, 031-01267-000, 031-01267-001, 031-01267-001A, 031-01284-000, 03101933000, 031-01933-000, 031-01972-000, 031-01973-000, 031-02166-000, 33101933000, 331-01933-000, 331-01972-200, 43101972100, 431-01972-100, P03101267001, P031-01267-001, P031-01267-001, PTH031011400-00
Lennox: G951ADB1401, G951ADB1401C, G951ADB-1401C, G951ADB1402, G951ADB-1402, G951AEB-1403
Goodman: 1809913, 18099-13S, B180996, B1809906, B18099-6, B18099-06, B1809908, B18099-08, B1809910, B18099-10, B18009910, B180099-10, B1809913, B18099-13, B1809913S, B18099-13S, B18009913, B180099-13
ICM: ICM280
White Rodgers: 50A55A843, 50T35730, 50T35-730, 50T35743, 50T35-743, 50A55-120, 50A55-143, 50A55-241, 50A55-285, 50A55-286, 50A55-288, 50A55-483, 50A55-(474-571), 50A55-843, 50A50-143, 50A50-209, 50A50-230, 50A50-285, 50A50-286, 50A50-438.
|